Procedure
Using a male threaded fitting
1. Loosen the nut on the stud fitting and remove it
2. Place the nut over the swaged end of the flexible hose
3. Place the pipe connector clamps in the housings on the hose
4. Slide the nut forward to the end of the flexible hose and assemble onto the male thread
5. Tighten the nut using the 2" – 2 1/2" spanner set

Using a pipe to pipe connector
1. Loosen the nut on the connector and remove it
2. Fit it over the swaged end of the flexible hose
3. Place the pipe connector clamps in the housings on the hose
4. Slide the nut forward to the end of the flexible hose, until it touches the clamps
5. Tighten the nut using the 2" – 2 1/2" spanner set

Using a 90° elbow
1. Loosen the nut on the elbow and remove it
2. Fit it over the swaged end of the flexible hose
3. Place the elbow clamps in the housings on the hose
4. Slide the nut forward to the end of the flexible hose, until it touches the clamps
5. Tighten the nut using the 2" – 2 1/2" spanner set