8"(220mm) pipe to pipe connectors can be quickly connected to Transair pipe.
Position the pipes together, install the seal, and close/
tighten the connector over the seal.
TUBE AND FITTINGS ASSEMBLY AND INSTALLATION INSTRUCTIONS
1 Component Inspection: Prior to assembly, a careful examination of the Tube
and Fittings must be performed. All components must be checked for correct
style, size, material, seal, and length. Inspect the Fitting and sealing surfaces
for burrs, nicks, corrosion, missing seal or other imperfections. Do NOT use any
component that displays any signs of nonconformance.
2 Tube and Fitting Assembly: Do not assemble a Parker Fitting with a Tube that is
not specifically listed by Parker for that Fitting, unless authorized in writing by
the engineering manager or chief engineer of the appropriate Parker division.
The Tube must meet the requirements specified to the Fitting. The Parker published
instructions must be followed for assembling the Fittings to a Tube.
TransairAluminumPipe.com is owned and operated by mdi, Manufacturers Distributor, Inc. mdi is an Authorized Parker Transair Piping System Distributor. Click Here to view the mdi Line Sheet. |